Cross Flow Closed Circuit Cooling Tower
Cross Flow Closed Circuit Cooling Tower reaches the ideal cooling effect through the assistance of water and air.Water and air as cooling medium exchange heat with high-temperature product,air inlet and air out from the top of cooling tower.
There are water distrubution system,condensing coils/plates,PVC Filler,Drift eliminator etc. as inside accessories and outside accessories such as pump,air inlet louver,Fan etc. complete the whole Device.

[ Technical Specification ]
The width of cooling tower evaperative condenser is no longer than 2.2m which designed specific to load container for smooth delivery.
Model | Rated Capacity | Fan | Spraying Pump | Operation Weight | ||||
Qty. | Power | Air Volume | Qty. | Power | Flow Rate | |||
RT | KW | m³/h | KW | m³/h | KG | |||
KCN-15 | 15 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 1280 |
KCN-25 | 25 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 1550 |
KCN-35 | 35 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 2100 |
KCN-45 | 45 | 2 | 2*1.1 | 2*15000 | 1 | 1*1.1 | 1*53 | 2300 |
KCN-55 | 55 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 2550 |
KCN-65 | 65 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 2600 |
KCN-80 | 80 | 2 | 2*2.2 | 2*26000 | 1 | 1*1.1 | 1*53 | 3400 |
KCN-90 | 90 | 1 | 1*5.5 | 1*60000 | 1 | 1*1.5 | 1*70 | 3800 |
KCN-105 | 105 | 1 | 1*5.5 | 1*60000 | 1 | 1*1.5 | 1*70 | 4200 |
KCN-125 | 125 | 1 | 1*5.5 | 1*80000 | 1 | 1*1.5 | 1*70 | 5380 |
KCN-135 | 135 | 1 | 1*7.5 | 1*90000 | 1 | 1*1.5 | 1*70 | 5800 |
KCN-160 | 160 | 1 | 1*11 | 1*125000 | 1 | 1*2.2 | 1*100 | 7400 |
KCN-180 | 180 | 1 | 1*11 | 1*125000 | 1 | 1*2.2 | 1*100 | 8200 |
KCN-200 | 200 | 2 | 2*4 | 2*55000 | 1 | 1*3 | 1*140 | 8700 |
KCN-220 | 220 | 2 | 2*5.5 | 2*60000 | 1 | 1*3 | 1*140 | 8900 |
KCN-240 | 240 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 9200 |
KCN-255 | 258 | 2 | 2*5.5 | 2*80000 | 1 | 1*4 | 1*180 | 9400 |
KCN-275 | 275 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 10500 |
KCN-290 | 290 | 2 | 2*11 | 2*125000 | 1 | 1*4 | 1*180 | 11900 |
KCN-315 | 315 | 2 | 2*11 | 2*125000 | 1 | 1*4 | 1*180 | 13350 |
KCN-330 | 330 | 2 | 2*7.5 | 2*90000 | 2 | 1*5.5 | 1*233 | 15000 |
Note: the 'Rated Capacity' based on standard condition: water inlet and outlet temp. 37-32degC, wet bulb temp. 28degC. |
[ Application ]

[ Key Projects ]

[ Workshop ]

[ our Activities ]


[ Why Choose Casen ]
1, Over 12 Year Experience In Cooling Tower System
2, +1200 Projects Installation Finished Over 35 Countries Worldwide
3, Computer Software Calculation, Performance 110% Reliable
4,Company had passed ISO9001, ISO14001 and OHSAS18001; 21 patents and certificates of CE, PED & SGS.
5, Professional Technical Team, Personal Customization Solution For You.