Stainless steel combined flow closed circuit cooling tower
ombined flow closed circuit cooling tower have water and air as cooling medium exchange heat with high-temperature Product inside the coils and bring the temperature down on basis of environment wet bulb temperature.Air and water flow toward the coil inside at the same direction,the spray water can cover the surface of the coil to get the ideal heat exchange area, at the same time,greatly reduce the formation of dry spots and water scale on the coil.

There are water distrubution system,condensing coils/plates,PVC Filler,Drift eliminator etc. as inside accessories and outside accessories such as pump,air inlet louver,Fan etc. completing the whole Device.


[ Technical Specification ]
The width of cooling tower evaperative condenser is no longer than 2.2m which designed specific to load container for smooth delivery.
Model | Rated Capacity | Fan | Spraying Pump | Operation Weight | ||||
Qty. | Power | Air Volume | Qty. | Power | Flow Rate | |||
RT | KW | m³/h | KW | m³/h | KG | |||
KCN-15 | 15 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 1280 |
KCN-25 | 25 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 1550 |
KCN-35 | 35 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 2100 |
KCN-45 | 45 | 2 | 2*1.1 | 2*15000 | 1 | 1*1.1 | 1*53 | 2300 |
KCN-55 | 55 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 2550 |
KCN-65 | 65 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 2600 |
KCN-80 | 80 | 2 | 2*2.2 | 2*26000 | 1 | 1*1.1 | 1*53 | 3400 |
KCN-90 | 90 | 1 | 1*5.5 | 1*60000 | 1 | 1*1.5 | 1*70 | 3800 |
KCN-105 | 105 | 1 | 1*5.5 | 1*60000 | 1 | 1*1.5 | 1*70 | 4200 |
KCN-125 | 125 | 1 | 1*5.5 | 1*80000 | 1 | 1*1.5 | 1*70 | 5380 |
KCN-135 | 135 | 1 | 1*7.5 | 1*90000 | 1 | 1*1.5 | 1*70 | 5800 |
KCN-160 | 160 | 1 | 1*11 | 1*125000 | 1 | 1*2.2 | 1*100 | 7400 |
KCN-180 | 180 | 1 | 1*11 | 1*125000 | 1 | 1*2.2 | 1*100 | 8200 |
KCN-200 | 200 | 2 | 2*4 | 2*55000 | 1 | 1*3 | 1*140 | 8700 |
KCN-220 | 220 | 2 | 2*5.5 | 2*60000 | 1 | 1*3 | 1*140 | 8900 |
KCN-240 | 240 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 9200 |
KCN-255 | 258 | 2 | 2*5.5 | 2*80000 | 1 | 1*4 | 1*180 | 9400 |
KCN-275 | 275 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 10500 |
KCN-290 | 290 | 2 | 2*11 | 2*125000 | 1 | 1*4 | 1*180 | 11900 |
KCN-315 | 315 | 2 | 2*11 | 2*125000 | 1 | 1*4 | 1*180 | 13350 |
KCN-330 | 330 | 2 | 2*7.5 | 2*90000 | 2 | 1*5.5 | 1*233 | 15000 |
Note: the 'Rated Capacity' based on standard condition: water inlet and outlet temp. 37-32degC, wet bulb temp. 28degC. |
[ Application ]
Heat Pump, Generating Set, Glass Melting Pit, Boiler Steam Condenses, Power Plant, Chemicals, Food, Cold Room, Pharmaceutical Factory etc.

[ Key Projects ]

[ Workshop ]

[ our Activities ]


[ Why Choose Casen ]
1, Over 12 Year Experience In Cooling Tower System
2, +1200 Projects Installation Finished Over 35 Countries Worldwide
3, Computer Software Calculation, Performance 110% Reliable
4,Company had passed ISO9001, ISO14001 and OHSAS18001;
5,21 patents and certificates of CE, PED & SGS.
6, Professional Technical Team, Personal Customization Solution For You.